7 resultados para Early stage breast cancer, Radiation therapy, Accelerated partial breast irradiation, External beam conformal radiation therapy, Lumpectomy, Target delineation, Fractionation, Whole breast radiation therapy

em RUN (Repositório da Universidade Nova de Lisboa) - FCT (Faculdade de Cienecias e Technologia), Universidade Nova de Lisboa (UNL), Portugal


Relevância:

100.00% 100.00%

Publicador:

Resumo:

RESUMO: Actualmente, a única possibilidade de cura para doentes com adenocarcinoma do pâncreas (PDAC) é a ressecção cirúrgica, no início deste estudo, perguntamo-nos se os predictores clínico-patológicos clássicos de prognostico poderiam ser validados em uma grande cohort de doentes com cancro do pâncreas ressecável e se outros predictores clínicos poderiam ter um papel na decisão de que doentes beneficiariam de ressecção cirúrgica. No capítulo 2, observamos que até 30% dos doentes morrem no primeiro ano após a ressecção cirúrgica, pelo que o nosso objectivo foi determinar factores pré-operatórios que se correlacionam com mortalidade precoce após ressecação cirúrgica com recurso a um instrumento estatisticamente validado, o Charlson-Age Comorbidity Index (CACI), determinamos que um CACI score superior a 4 foi preditivo de internamentos prolongados (p <0,001), complicações pós-operatórias (p = 0,042), e mortalidade em 1 ano pós- ressecção cirúrgica (p <0,001). Um CACI superior a 6 triplicou a mortalidade no primeiro ano pós-cirurgia e estes doentes têm menos de 50% de probabilidade de estarem vivos um ano após a cirurgia. No capítulo 3, o nosso objectivo foi identificar uma proteína de superfície que se correlacionasse estatisticamente com o prognostico de doentes com adenocarcinoma do pâncreas e permitisse a distinção de subgrupos de doentes de acordo com as suas diferenças moleculares, perguntamo-nos ainda se essa proteína poderia ser um marcador de células-estaminais. No nosso trabalho anterior observamos que as células tumorais na circulação sanguínea apresentavam genes com características bifenotípica epitelial e mesenquimal, enriquecimento para genes de células estaminais (ALDH1A1 / ALDH1A2 e KLF4), e uma super-expressão de genes da matriz extracelular (colagénios, SPARC, e DCN) normalmente identificados no estroma de PDAC. Após a avaliação dos tumores primários com RNA-ISH, muitos dos genes identificados, foram encontrados co-localizando em uma sub-população de células na região basal dos ductos pancreáticos malignos. Além disso, observamos que estas células expressam o marcador SV2A neuroendócrino, e o marcador de células estaminais ALDH1A1/2. Em comparação com tumores negativos para SV2, os doentes com tumores SV2 positivos apresentaram níveis mais baixos de CA 19-9 (69% vs. 52%, p = 0,012), tumores maiores (> 4 cm, 23% vs. 10%, p = 0,0430), menor invasão de gânglios linfáticos (69% vs. 86%, p = 0,005) e tumores mais diferenciados (69% vs. 57%, p = 0,047). A presença de SV2A foi associada com uma sobrevida livre de doença mais longa (HR: 0,49 p = 0,009) bem como melhor sobrevida global (HR: 0,54 p = 0,018). Em conjunto, esta informação aponta para dois subtipos diferentes de adenocarcinoma do pâncreas, e estes subtipos co-relacionam estatisticamente com o prognostico de doentes, sendo este subgrupo definido pela presença do clone celular SV2A / ALDH1A1/2 positivo com características neuroendócrinas. No Capítulo 4, a expressão de SV2A no cancro do pâncreas foi validado em linhas celulares primárias. Demonstramos a heterogeneidade do adenocarcinoma do pâncreas de acordo com características clonais neuroendócrinas. Ao comparar as linhas celulares expressando SV2 com linhas celulares negativas, verificamos que as linhas celulares SV2+ eram mais diferenciadas, diferindo de linhas celulares SV2 negativas no que respeita a mutação KRAS, proliferação e a resposta à quimioterapia. No capítulo 5, perguntamo-nos se o clone celular SV2 positivo poderia explicar a resistência a quimioterapia observada em doentes. Observamos um aumento absoluto de clones celulares expressando SV2A, em múltiplas linhas de evidência - doentes, linhas de células primárias e xenotransplantes. Embora, tenhamos sido capazes de demonstrar que o adenocarcinoma do pâncreas é uma doença heterogénea, consideramos que a caracterização genética destes clones celulares expressando SV2A é de elevada importância. Pretendemos colmatar esta limitação com as seguintes estratégias: Após o tratamento com quimioterapia neoadjuvante na nossa coorte, realizamos microdissecação a laser das amostras primarias em parafina, de forma a analisar mutações genéticas observadas no adenocarcinoma pancreático; em segundo lugar, pretendemos determinar consequências de knockdown da expressão de SV2A em nossas linhas celulares seguindo-se o tratamento com gemicitabina para determinação do papel funcional de SV2A; finalmente, uma vez que os nossos esforços anteriores com um promotor - repórter e SmartFlare ™ falharam, o próximo passo será realizar RNA-ISH PrimeFlow™ seguido de FACS e RNA-seq para caracterização deste clone celular. Em conjunto, conseguimos provar com várias linhas de evidência, que o adenocarcinoma pancreático é uma doença heterogénea, definido por um clone de células que expressam SV2A, com características neuroendócrinas. A presença deste clone no tecido de doentes correlaciona-se estatisticamente com o prognostico da doença, incluindo sobrevida livre de doença e sobrevida global. Juntamente com padrões de proliferação e co-expressão de ALDH1A1/2, este clone parece apresentar um comportamento de células estaminais e está associado a resistência a quimioterapia, uma vez que a sua expressão aumenta após agressão química, quer em doentes, quer em linhas de células primárias.----------------------------- ABSTRACT: Currently, the only chance of cure for patients with pancreatic adenocarcinoma is surgical resection, at the beginning of my thesis studies, we asked if the classical clinicopathologic predictors of outcome could be validated in a large cohort of patients with early stage pancreatic cancer and if other clinical predictors could have a role on deciding which patients would benefit from surgery. In chapter 2, we found that up to 30% of patients die within the first year after curative intent surgery for pancreatic adenocarcinoma. We aimed at determining pre-operative factors that would correlate with early mortality following resection for pancreatic cancer using a statistically validated tool, the Charlson-Age Comorbidity Index (CACI). We found that a CACI score greater than 4 was predictive of increased length of stay (p<0.001), post-operative complications (p=0.042), and mortality within 1-year of pancreatic resection (p<0.001). A CACI score of 6 or greater increased 3-fold the odds of death within the first year. Patients with a high CACI score have less than 50% likelihood of being alive 1 year after surgery. In chapter 3 we aimed at identifying a surface protein that correlates with patient’s outcome and distinguishes sub-groups of patients according to their molecular differences and if this protein could be a cancer stem cell marker. The most abundant class of circulating tumor cells identified in our previous work was found to have biphenotypic features of epithelial to mesenchymal transition, enrichment for stem-cell associated genes (ALDH1A1/ALDH1A2 and KLF4), and an overexpression of extracellular matrix genes (Collagens, SPARC, and DCN) normally found in the stromal microenvironment of PDAC primary tumors. Upon evaluation of matched primary tumors with RNA-ISH, many of the genes identified were found to co-localize in a sub-population of cells at the basal region of malignant pancreatic ducts. In addition, these cells expressed the neuroendocrine marker SV2A, and the stem cell marker ALDH1A1/2. Compared to SV2 negative tumors, patients with SV2 positive tumors were more likely to present with lower CA 19-9 (69% vs. 52%, p = 0.012), bigger tumors (size > 4 cm, 23% vs. 10%, p= 0.0430), less nodal involvement (69% vs. 86%, p = 0.005) and lower histologic grade (69% vs. 57%, p = 0.047). The presence of SV2A expressing cells was associated with an improved disease free survival (HR: 0.49 p=0.009) and overall survival (HR: 0.54 p=0.018) and correlated linearly with ALDH1A2. Together, this information points to two different sub-types of pancreatic adenocarcinoma, and these sub-types correlated with patients’ outcome and were defined by the presence of a SV2A/ ALDH1A1/2 expressing clone with neuroendocrine features. In Chapter 4, SV2A expression in cancer was validated in primary cell lines. We were able to demonstrate pancreatic adenocarcinoma heterogeneity according to neuroendocrine clonal features. When comparing SV2 expressing cell lines with SV2 negative cell lines, we found that SV2+ cell lines were more differentiated and differ from SV2 negative cell lines regarding KRAS mutation, proliferation and response to chemotherapy. In Chapter 5 we aimed at determining if this SV2 positive clone could explain chemoresistance observed in patients. We found an absolute increase in SV2A expressing cells, with multiple lines of evidence, in patients, primary cell lines and xenografts. Although, we have been able to show evidence that pancreatic adenocarcinoma is a heterogeneous disease, our findings warrant further investigation. To further characterize SV2A expressing clones after treatment with neoadjuvant chemotherapy in our cohort, we have performed laser capture microdissection of the paraffin embedded tissue in this study and will analyze the tissue for known genetic mutations in pancreatic adenocarcinoma; secondly, we want to know what will happen after knocking down SV2A expression in our cell lines followed by treatment with gemcitabine to determine if SV2A is functionally important; finally, since our previous efforts with a promoter – reporter and SmartFlare™ have failed, we will utilize a novel PrimeFlow™ RNA-ISH assay followed by FACS and RNA sequencing to further characterize this cellular clone. Overall our data proves, with multiple lines of evidence, that pancreatic adenocarcinoma is a heterogeneous disease, defined by a clone of SV2A expressing cells, with neuroendocrine features. The presence of this clone in patients’ tissue correlates with patient’s disease free survival and overall survival. Together with patterns of proliferation and ALDH1A1/2 co-expression, this clone seems to present a stem-cell-like behavior and is associated with chemoresistance, since it increases after chemotherapy, both in patients and primary cell lines.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

RESUMO: O cancro de mama e o mais frequente diagnoticado a indiv duos do sexo feminino. O conhecimento cientifico e a tecnologia tem permitido a cria ção de muitas e diferentes estrat egias para tratar esta patologia. A Radioterapia (RT) est a entre as diretrizes atuais para a maioria dos tratamentos de cancro de mama. No entanto, a radia ção e como uma arma de dois canos: apesar de tratar, pode ser indutora de neoplasias secund arias. A mama contralateral (CLB) e um orgão susceptivel de absorver doses com o tratamento da outra mama, potenciando o risco de desenvolver um tumor secund ario. Nos departamentos de radioterapia tem sido implementadas novas tecnicas relacionadas com a radia ção, com complexas estrat egias de administra ção da dose e resultados promissores. No entanto, algumas questões precisam de ser devidamente colocadas, tais como: E seguro avançar para tecnicas complexas para obter melhores indices de conformidade nos volumes alvo, em radioterapia de mama? O que acontece aos volumes alvo e aos tecidos saudaveis adjacentes? Quão exata e a administração de dose? Quais são as limitações e vantagens das técnicas e algoritmos atualmente usados? A resposta a estas questões e conseguida recorrendo a m etodos de Monte Carlo para modelar com precisão os diferentes componentes do equipamento produtor de radia ção(alvos, ltros, colimadores, etc), a m de obter uma descri cão apropriada dos campos de radia cão usados, bem como uma representa ção geometrica detalhada e a composição dos materiais que constituem os orgãos e os tecidos envolvidos. Este trabalho visa investigar o impacto de tratar cancro de mama esquerda usando diferentes tecnicas de radioterapia f-IMRT (intensidade modulada por planeamento direto), IMRT por planeamento inverso (IMRT2, usando 2 feixes; IMRT5, com 5 feixes) e DCART (arco conformacional dinamico) e os seus impactos em irradia ção da mama e na irradia ção indesejada dos tecidos saud aveis adjacentes. Dois algoritmos do sistema de planeamento iPlan da BrainLAB foram usados: Pencil Beam Convolution (PBC) e Monte Carlo comercial iMC. Foi ainda usado um modelo de Monte Carlo criado para o acelerador usado (Trilogy da VARIAN Medical Systems), no c odigo EGSnrc MC, para determinar as doses depositadas na mama contralateral. Para atingir este objetivo foi necess ario modelar o novo colimador multi-laminas High- De nition que nunca antes havia sido simulado. O modelo desenvolvido est a agora disponí vel no pacote do c odigo EGSnrc MC do National Research Council Canada (NRC). O acelerador simulado foi validado com medidas realizadas em agua e posteriormente com c alculos realizados no sistema de planeamento (TPS).As distribui ções de dose no volume alvo (PTV) e a dose nos orgãos de risco (OAR) foram comparadas atrav es da an alise de histogramas de dose-volume; an alise estati stica complementar foi realizadas usando o software IBM SPSS v20. Para o algoritmo PBC, todas as tecnicas proporcionaram uma cobertura adequada do PTV. No entanto, foram encontradas diferen cas estatisticamente significativas entre as t ecnicas, no PTV, nos OAR e ainda no padrão da distribui ção de dose pelos tecidos sãos. IMRT5 e DCART contribuem para maior dispersão de doses baixas pelos tecidos normais, mama direita, pulmão direito, cora cão e at e pelo pulmão esquerdo, quando comparados com as tecnicas tangenciais (f-IMRT e IMRT2). No entanto, os planos de IMRT5 melhoram a distribuição de dose no PTV apresentando melhor conformidade e homogeneidade no volume alvo e percentagens de dose mais baixas nos orgãos do mesmo lado. A t ecnica de DCART não apresenta vantagens comparativamente com as restantes t ecnicas investigadas. Foram tamb em identi cadas diferen cas entre os algoritmos de c alculos: em geral, o PBC estimou doses mais elevadas para o PTV, pulmão esquerdo e cora ção, do que os algoritmos de MC. Os algoritmos de MC, entre si, apresentaram resultados semelhantes (com dferen cas at e 2%). Considera-se que o PBC não e preciso na determina ção de dose em meios homog eneos e na região de build-up. Nesse sentido, atualmente na cl nica, a equipa da F sica realiza medi ções para adquirir dados para outro algoritmo de c alculo. Apesar de melhor homogeneidade e conformidade no PTV considera-se que h a um aumento de risco de cancro na mama contralateral quando se utilizam t ecnicas não-tangenciais. Os resultados globais dos estudos apresentados confirmam o excelente poder de previsão com precisão na determinação e c alculo das distribui ções de dose nos orgãos e tecidos das tecnicas de simulação de Monte Carlo usados.---------ABSTRACT:Breast cancer is the most frequent in women. Scienti c knowledge and technology have created many and di erent strategies to treat this pathology. Radiotherapy (RT) is in the actual standard guidelines for most of breast cancer treatments. However, radiation is a two-sword weapon: although it may heal cancer, it may also induce secondary cancer. The contralateral breast (CLB) is a susceptible organ to absorb doses with the treatment of the other breast, being at signi cant risk to develop a secondary tumor. New radiation related techniques, with more complex delivery strategies and promising results are being implemented and used in radiotherapy departments. However some questions have to be properly addressed, such as: Is it safe to move to complex techniques to achieve better conformation in the target volumes, in breast radiotherapy? What happens to the target volumes and surrounding healthy tissues? How accurate is dose delivery? What are the shortcomings and limitations of currently used treatment planning systems (TPS)? The answers to these questions largely rely in the use of Monte Carlo (MC) simulations using state-of-the-art computer programs to accurately model the di erent components of the equipment (target, lters, collimators, etc.) and obtain an adequate description of the radiation elds used, as well as the detailed geometric representation and material composition of organs and tissues. This work aims at investigating the impact of treating left breast cancer using di erent radiation therapy (RT) techniques f-IMRT (forwardly-planned intensity-modulated), inversely-planned IMRT (IMRT2, using 2 beams; IMRT5, using 5 beams) and dynamic conformal arc (DCART) RT and their e ects on the whole-breast irradiation and in the undesirable irradiation of the surrounding healthy tissues. Two algorithms of iPlan BrainLAB TPS were used: Pencil Beam Convolution (PBC)and commercial Monte Carlo (iMC). Furthermore, an accurate Monte Carlo (MC) model of the linear accelerator used (a Trilogy R VARIANR) was done with the EGSnrc MC code, to accurately determine the doses that reach the CLB. For this purpose it was necessary to model the new High De nition multileaf collimator that had never before been simulated. The model developed was then included on the EGSnrc MC package of National Research Council Canada (NRC). The linac was benchmarked with water measurements and later on validated against the TPS calculations. The dose distributions in the planning target volume (PTV) and the dose to the organs at risk (OAR) were compared analyzing dose-volume histograms; further statistical analysis was performed using IBM SPSS v20 software. For PBC, all the techniques provided adequate coverage of the PTV. However, statistically significant dose di erences were observed between the techniques, in the PTV, OAR and also in the pattern of dose distribution spreading into normal tissues. IMRT5 and DCART spread low doses into greater volumes of normal tissue, right breast, right lung, heart and even the left lung than tangential techniques (f-IMRT and IMRT2). However,IMRT5 plans improved distributions for the PTV, exhibiting better conformity and homogeneity in target and reduced high dose percentages in ipsilateral OAR. DCART did not present advantages over any of the techniques investigated. Di erences were also found comparing the calculation algorithms: PBC estimated higher doses for the PTV, ipsilateral lung and heart than the MC algorithms predicted. The MC algorithms presented similar results (within 2% di erences). The PBC algorithm was considered not accurate in determining the dose in heterogeneous media and in build-up regions. Therefore, a major e ort is being done at the clinic to acquire data to move from PBC to another calculation algorithm. Despite better PTV homogeneity and conformity there is an increased risk of CLB cancer development, when using non-tangential techniques. The overall results of the studies performed con rm the outstanding predictive power and accuracy in the assessment and calculation of dose distributions in organs and tissues rendered possible by the utilization and implementation of MC simulation techniques in RT TPS.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Mestre em Engenharia Química e Bioquímica

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A Work Project, presented as part of the requirements for the Award of a Masters Degree in Management from the NOVA – School of Business and Economics

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Information technologies (ITs), and sports resources and services aid the potential to transform governmental organizations, and play an important role in contributing to sustainable communities development, respectively. Spatial data is a crucial source to support sports planning and management. Low-cost mobile geospatial tools bring productive and accurate data collection, and their use combining a handy and customized graphical user interface (GUI) (forms, mapping, media support) is still in an early stage. Recognizing the benefits — efficiency, effectiveness, proximity to citizens — that Mozambican Minister of Youth and Sports (MJD) can achieve with information resulted from the employment of a low-cost data collection platform, this project presents the development of a mobile mapping application (app) — m-SportGIS — under Open Source (OS) technologies and a customized evolutionary software methodology. The app development embraced the combination of mobile web technologies and Application Programming Interfaces (APIs) (e.g. Sencha Touch (ST), Apache Cordova, OpenLayers) to deploy a native-to-the-device (Android operating system) product, taking advantage of device’s capabilities (e.g. File system, Geolocation, Camera). In addition to an integrated Web Map Service (WMS), was created a local and customized Tile Map Service (TMS) to serve up cached data, regarding the IT infrastructures limitations in several Mozambican regions. m-SportGIS is currently being exploited by Mozambican Government staff to inventory all kind of sports facilities, which resulted and stored data feeds a WebGIS platform to manage Mozambican sports resources.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This report will describe the activities undertaken during my internship at the Personnel Department (DPE-UPE4.1) in Caixa Geral de Depósitos (CGD), Lisbon, between September 22, 2014, and February 28, 2015. I consider that it is important to note from the outset i) that the subject of my training was suggested by my supervisor in the DPE and accepted by me; and ii) that the internship consisted essentially of carrying out research and information gathering into the different social systems that coexist within the bank and the application of each legal system in solving concrete situations of the CGD employees. The research and analysis of information was important not only for my study but for the CGD itself, as it enables the department to have such an important matter, full of specific characteristics, condensed into a single document, i.e. this report. This is a complex reality. The various welfare systems differ according to the contractual agreement linking the employee to the employer at the date when the labour contract is signed, and also the unique/singular characteristics of the CGD. In the early stage I started by trying to understand the financial institution and its organization and role and the department where I worked. So I analyzed the CGD Statutes and the legal measures that crystallized the scheme for its employees and I also researched its domestic and international operations. The first month was devoted to the research and analysis of such legislation to understand the creation of the CGD and its path to date. In the second and third months I studied the legal social systems that are applied to different groups of CGD workers. This period was quite important to identify and understand the differences between those regimes of CGD employees as well as the procedure inherent in each case. I highlighted the non-implementation of “the social protection regime of convergence” to the workers of this institution; the differences regarding the allocation of sickness subsidies paid to workers who belong to Social Security and CGA contributors, as well as the enforcement of internal rules to all the workers when a work-related accident happens.Then I focused on to assessing and examining external legislation and several internal regulations in order to obtain solutions to questions raised and situations involving by the workers, in order to understand how the DPE solves these situations. Over the last three months of internship, after this more theoretical work, I began the analysis of concrete situations involving employees carrying out their duties in Portugal and abroad. Some of these situations had been received by the department before the beginning of my internship and others over this period. When I was “working” in the DPE I analyzed “cases” that had been solved and some others without a final solution because they were still in courts. As for the last ones (new cases) I was able to follow their assessment and sometimes their outcome. Some of them became study cases for me. Over these five months of my internship, several cases were analyzed and discussed by legal experts of DPE in which I could participate. I always worked hard. I know that this action contributed to elucidate me about the treatment of the issues, and allowed me to have a direct contact with some workers and be part of a dynamic work team. For these reasons, my internship report is not merely descriptive of activities. It consists of an analysis of rules (legislation) and a regulatory framework of activities and it is also a description of several specific situations solved or in a solution process. Through this work I intend to make known the particular reality of a modern Portuguese financial institution not only because of its importance in our country but also such a large number of employees work here (in Portugal and abroad). I should add that throughout my internship I was allowed to attend conferences, within the scope of the bank in order to get a broader view of some issues related to the daily life of the DPE and the CGD. So, I participated in I Jornadas Bancárias and the Conferência Internacional do Contrato a Termo, given that the CGD is a bank and the DPE deals with legal and labour relations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

RESUMO: Este trabalho teve como objetivo a determinação de esquemas de tratamento alternativos para o carcinoma da próstata com radioterapia externa (EBRT) e braquiterapia de baixa taxa de dose (LDRBT) com implantes permanentes de Iodo-125, biologicamente equivalentes aos convencionalmente usados na prática clínica, com recurso a modelos teóricos e a métodos de Monte Carlo (MC). Os conceitos de dose biológica efetiva (BED) e de dose uniforme equivalente (EUD) foram utilizados, com o modelo linear-quadrático (LQ), para a determinação de regimes de tratamento equivalentes. Numa primeira abordagem, utilizou-se a BED para determinar: 1) esquemas hipofracionados de EBRT mantendo as complicações retais tardias de regimes convencionais com doses totais de 75,6 Gy, 77,4 Gy, 79,2 Gy e 81,0 Gy; e 2) a relação entre as doses totais de EBRT e LDRBT de modo a manter a BED do regime convencional de 45 Gy de EBRT e 110 Gy de LDRBT. Numa segunda abordagem, recorreu-se ao código de MC MCNPX para a simulação de distribuições de dose de EBRT e LDRBT em dois fantomas de voxel segmentados a partir das imagens de tomografia computorizada de pacientes com carcinoma da próstata. Os resultados das simulações de EBRT e LDRBT foram somados e determinada uma EUD total de forma a obterem-se: 1) esquemas equivalentes ao tratamento convencional de 25 frações de 1,8 Gy de EBRT em combinação com 110 Gy de LDRBT; e 2) esquemas equivalentes a EUD na próstata de 67 Gy, 72 Gy, 80 Gy, 90 Gy, 100 Gy e 110 Gy. Em todos os resultados nota-se um ganho terapêutico teórico na utilização de esquemas hipofracionados de EBRT. Para uma BED no reto equivalente ao esquema convencional, tem-se um aumento de 2% na BED da próstata com menos 5 frações. Este incremento dá-se de forma cada vez mais visível à medida que se reduz o número de frações, sendo da ordem dos 10-11% com menos 20 frações e dos 35-45% com menos 40 frações. Considerando os resultados das simulações de EBRT, obteve-se uma EUD média de 107 Gy para a próstata e de 42 Gy para o reto, com o esquema convencional de 110 Gy de LDRBT, seguidos de 25 frações de 1,8 Gy de EBRT. Em termos de probabilidade de controlo tumoral (igual EUD), é equivalente a este tratamento a administração de EBRT em 66 frações de 1,8 Gy, 56 de 2 Gy, 40 de 2,5 Gy, 31 de 3 Gy, 20 de 4 Gy ou 13 de 5 Gy. Relativamente à administração de 66 frações de 1,8 Gy, a EUD generalizada no reto reduz em 6% com o recurso a frações de 2,5 Gy e em 10% com frações de 4 Gy. Determinou-se uma BED total de 162 Gy para a administração de 25 frações de 1,8 Gy de EBRT em combinação com 110 Gy de LDRBT. Variando-se a dose total de LDRBT (TDLDRBT) em função da dose total de EBRT (TDEBRT), de modo a garantir uma BED de 162 Gy, obteve-se a seguinte relação:.......... Os resultados das simulações mostram que a EUD no reto diminui com o aumento da dose total de LDRBT para dose por fração de EBRT (dEBRT) inferiores a 2, Gy e aumenta para dEBRT a partir dos 3 Gy. Para quantidades de TDLDRBT mais baixas (<50 Gy), o reto beneficia de frações maiores de EBRT. À medida que se aumenta a TDLDRBT, a EUD generalizada no reto torna-se menos dependente da dEBRT. Este trabalho mostra que é possível a utilização de diferentes regimes de tratamento para o carcinoma da próstata com radioterapia que possibilitem um ganho terapêutico, quer seja administrando uma maior dose biológica com efeitos tardios constantes, quer mantendo a dose no tumor e diminuindo a toxicidade retal. A utilização com precaução de esquemas hipofracionados de EBRT, para além do benefício terapêutico, pode trazer vantagens ao nível da conveniência para o paciente e economia de custos. Os resultados das simulações deste estudo e conversão para doses de efeito biológico para o tratamento do carcinoma da próstata apresentam linhas de orientação teórica de interesse para novos ensaios clínicos. --------------------------------------------------ABSTRACT: The purpose of this work was to determine alternative radiotherapy regimens for the treatment of prostate cancer using external beam radiotherapy (EBRT) and low dose-rate brachytherapy (LDRBT) with Iodine-125 permanent implants which are biologically equivalent to conventional clinical treatments, by the use of theoretical models and Monte Carlo techniques. The concepts of biological effective dose (BED) and equivalent uniform dose (EUD), together with the linear-quadratic model (LQ), were used for determining equivalent treatment regimens. In a first approach, the BED concept was used to determine: 1) hypofractionated schemes of EBRT maintaining late rectal complications as with the conventional regimens with total doses of 75.6 Gy, 77.4 Gy, 79.2 Gy and 81.0 Gy; and 2) the relationship between total doses of EBRT and LDRBT in order to keep the BED of the conventional treatment of 45 Gy of EBRT and 110 Gy of LDRBT. In a second approach, the MC code MCNPX was used for simulating dose distributions of EBRT and LDRBT in two voxel phantoms segmented from the computed tomography of patients with prostate cancer. The results of the simulations of EBRT and LDRBT were added up and given an overall EUD in order to obtain: 1) equivalent to conventional treatment regimens of 25 fraction of 1.8 Gy of EBRT in combination with 110Gy of LDRBT; and 2) equivalent schemes of EUD of 67 Gy, 72 Gy, 80 Gy, 90 Gy, 100 Gy, and 110Gy to the prostate. In all the results it is noted a therapeutic gain using hypofractionated EBRT schemes. For a rectal BED equivalent to the conventional regimen, an increment of 2% in the prostate BED was achieved with less 5 fractions. This increase is visibly higher as the number of fractions decrease, amounting 10-11% with less 20 fractions and 35-45% with less 20 fractions. Considering the results of the EBRT simulations an average EUD of 107 Gy was achieved for the prostate and of 42 Gy for the rectum with the conventional scheme of 110 Gy of LDRBT followed by 25 fractions of 1.8 Gy of EBRT. In terms of tumor control probability (same EUD) it is equivalent to this treatment, for example, delivering the EBRT in 66 fractions of 1.8 Gy, 56 fractions of 2 Gy, 40 fractions of 2.5 Gy, 31 fractions of 3 Gy, 20 fractions of 4 Gy or 13 fractions of 5 Gy. Regarding the use of 66 fractions of 1.8 Gy, the rectum EUD is reduced to 6% with 2.5 Gy per fraction and to 10% with 4 Gy. A total BED of 162 Gy was achieved for the delivery of 25 fractions of 1.8 Gy of EBRT in combination with 110 Gy of LDRBT. By varying the total dose of LDRBT (TDLDRBT) with the total dose of EBRT (TDEBRT) so as to ensure a BED of 162 Gy, the following relationship was obtained: ....... The simulation results show that the rectum EUD decreases with the increase of the TDLDRBT, for EBRT dose per fracion (dEBRT) less than 2.5 Gy and increases for dEBRT above 3 Gy. For lower amounts of TDLDRBT (< 50Gy), the rectum benefits of larger EBRT fractions. As the TDLDRBT increases, the rectum gEUD becomes less dependent on the dEBRT. The use of different regimens which enable a therapeutic gain, whether deivering a higher dose with the same late biological effects or maintaining the dose to the tumor and reducing rectal toxicity is possible. The use with precaution of hypofractionated regimens, in addition to the therapeutic benefit, can bring advantages in terms of convenience for the patient and cost savings. The simulation results of this study together with the biological dose conversion for the treatment of prostate cancer serve as guidelines of interest for new clinical trials.